Operation Cost Savings

Operating Cost Savings

An air compressor is regarded as the noisy box on the side of a workshop, it is typically forgotten about unless it is being serviced or switched on and off at the start and end of the day. However your air compressor could be costing you thousands of dollars in operating costs.

Air plumbing

  • Any air leak in your facility is costing you money, air leaking from a hose or fitting slowly reduces the capacity inside the receiver tank and causes the workshop compressor to load up and maintain pressure. Removing air leaks maintains tank pressures and reduces the start up of the air compressor when not in use.
  • Reducing the pipework within the workplace decreases the amount of air required in the system.

Switching the compressor off

  • Why should your compressor run whilst the workplace is empty. If the compressed air is not required switching the compressor off during Holiday shut downs or after hours will prevent the compressor from refilling the receiver tank.
  • Install an automatic shutdown timer.

Servicing

  • Ensure high quality filters and oil are used in the routine service a poor quality air filter may cause a restriction and therefore reduce the efficiency of the compressor increasing heat, and operating costs.
  • Cleaning the compressors oil cooler and after-cooler not only ensures the cooling system is operating at an optimal level but reduces the pressure dewpoint of the compressed air.
  • In the situation where the compressor is fitted with a drive belt or chain, if these are incorrectly adjusted whether the belt or chain is too tight/loose. This can cause the compressor pulley to slip in high demand occasions when too loose. When the chain or belt is too tight this can cause premature wear to the bearings and pulleys increasing operation costs to the compressor.

Air pressure

  • Setting the loading and unloading pressure of the compressor reduces energy costs by reducing the work of the compressor. For example if the workplace only requires a maximum of 100PSI of pressure, working the compressor to 130PSI would be inefficient and wasting energy

Compressor Size

  • An important design consideration for a workplace or process plant is to ensure that the compressor is correctly sized for the application, selecting a compressor which is too small for the application will cause the compressor to be playing catch up and never unloading. This will reduce the life of the machine and increase the operation costs of the compressor.
  • Air receiver tanks are used to store compressed air for the workplace. Having a correctly size air receiver tank is equally as important as selecting the correctly sized air compressor.
  • If the demand is necessary it may be recommended to purchase a second air compressor. Having a “Lead/Lag” operation of the compressor reduces operating costs by using only one compressor to operate during low demand timing, however allows for high output in busy periods.